CLINICAL STUDIES CLINICAL COMPARISON OF THE TONOVET REBOUND TONOMETER AND THE TONO-PEN VET APPLANATION TONOMETER IN DOGS AND CATS WITH OCULAR DISEASE: GLAUCOMA OR CORNEAL PATHOLOGY Lena von Spiessen, Julia Karck, Karl Rohn and Andrea Meyer-Lindenberg Klinik für Kleintiere, Stiftung Tierärztliche Hochschule Hannover, Bünteweg 9, 30559 Hannover, Germany; Chirurgische und Gynäkologische Kleintierklinik, Ludwig-Maximilians-Uni- versität München, Veterinärstr. 13, 80539 München, Germany; and Institut für Biometrie, Epidemiologie und Informationsverarbeitung, Stiftung Tierärztliche Hochschule Hannover, Bünteweg 2, 30559 Hannover, Germany OBJECTIVE To compare the TONOVET rebound tonometer with the Tono-Pen Vet applanation tonometer in a larger number of glaucomatous eyes and to evaluate the effect of different corneal pathologies on both tonometers. PROCEDURE In 26 eyes with clinical signs of glaucoma, intraocular pressure (IOP) was measured using the TONOVET followed by the Tono-Pen Vet. In 29 eyes with focal corneal pathology (e.g., corneal scarring, edema, pigmentation), both tonometers were used successively to measure IOP in one unaffected area of the cornea, as well as on the lesion itself. Impact on measurement results was assessed comparing the deviation in IOP readings of each tonometer between the two localizations. Statistical data analysis included paired t-tests and regression analysis using SAS software (version 9.2; SAS Institute, Cary, NC). RESULTS In glaucomatous eyes, the TONOVET consistently yielded higher values of IOP than the Tono-Pen Vet as can be quantified by the regression equation IOP (TonoVet) [mmHg] = 1.12 * IOP (Tono-Pen Vet) [mmHg] + 11.5 with R2 = 0.91 and P < 0.0001. Depending on the type and degree of corneal pathology, the deviation in IOP resulting from measurements on altered cornea ranged from 6 to 16 mmHg for the TONOVET and 7 to 20 mmHg for the Tono-Pen Vet, respectively. On average, the effect of corneal disease on IOP measurements was lower for the TonoVet by 1.14 mmHg. CONCLUSIONS Rebound tonometry appears to be a valuable alternative to established applanation tonometry in patients with ocular disease such as glaucoma and corneal disorders. In patients suffering from glaucoma, the same type of tonometer should be used for follow-up examinations, as measurement results of the TONOVET and the Tono-Pen Vet differ substantially with increasing IOP. Corneal pathology has considerable influence on both tonometers with the degree of over- or underestimation of IOP depending on the alteration of biomechanical properties of the cornea inflicted by various corneal pathologies. © Veterinary Ophthalmology, 2013 25
TONOVET DNA Clinical Studies, Articles, Testimonials Literature – LITJ1000-4
Title Name |
Pages |
Delete |
Url |
Empty |
AI Assistant
Ask anything about this document
AI is thinking…
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
0% - Preparing download...
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait